HSSCseries

Specification

Dimension

50kPa~3MPa

HSSC

Battery-operated digital display requires no wiring.
Constructed with stainless steel in view of environmental resistance.
Standard functions include max/min pressure monitoring, auto-zero and peak hold.
Diaphragm with overwhelming durability provides safe and reliable construction.
Safe and reliable construction with no sealed liquid.

Measured mediumAlcohols, milk beverage, seasoning, pure water, chemical or other media.
(These vary according to sensor materials)
Pressure typePositive, compound, and negative pressures can be measured.
Pressure range(*1) Specify from the list of ranges.
Output typeNone
Moving averageCan be selected among 1, 2, 4, 8, 16, 32, 64, and 128 times.

Specification 1 (Sensor assembly)

Pressure Port Type/SizeISO Ferrule, VARIVENT®, ISO Cap nut, Other special orders
Rated Capacity(R.C.)50, 100, 200, 300, 500, 1000kPa, 3MPa
MaterialSensor: SUS316L / Hastelloy C276 / SUS329J4L
Finish(Sensor Part)Electro-Chemical Buffing
Safe Overload Rating400%R.C. (Rated capacity 3MPa: 150%R.C.)
Destruction Point1000%R.C. (Rated capacity 3MPa: 300%R.C.)

Specification 2 (Amplifier + Sensor assembly)

Non Linearity±0.5%R.C.
Hysteresis±0.5%R.C.
Compensated Temperature Range (Wetted part)-5~150?C
Safe Temperature Range (Wetted part)-5~150?C
Temperature Effect on Zero Balance±0.5%R.C./10?C (Rating: 300, 500, 1000kPa, 3MPa)
±0.7%R.C./10?C (Rating: 50, 100, 200kPa)
Temperature Effect on Load±0.5%R.C./10?C (Rating: 300, 500, 1000kPa, 3MPa)
±0.7%R.C./10?C (Rating: 50, 100, 200kPa)
Ambient Temperature and HumidityTemperature:0~50?C(No freezing), Humidity:0~90%RH(No condensation)
FunctionsMaximum / Minimum monitor, Peak hold, Auto zero, Auto power OFF function(*2)
MaterialSUS304(Case material), SUS304(Radiating fin)
IP RatingEquivalent to IP65
WeightApprox. 670g
AccessoriesOperation manual (1 copy), Test report (1 copy)
Display bracket ×1(Separate type), Battery for monitors

Model Selection

Model Selection

SelectionCheckModelSpecification
1.ModelHSSCHigh temperature type: Temperature range of wetted parts -5~150?C
2.DisplayD4 digit LCD Character height: 12.7mm
Can be selected display cycle: 125ms/250ms/500ms/1s/2s/5s/10s (Factory setting 1sec)
3.Sensor Connection
ASSensor directly connected on bottom

PA05Display part: Vertical piping erection sensor
(Display part~Cable between the sensor 5m)
*Sensor sparate

PA10Display part: Vertical piping erection sensor
(Display part~Cable between the sensor 10m)
*Sensor sparate

PB05Display part: Horizontal piping erection sensor
(Display part~Cable between the sensor 5m)
*Sensor sparate

PB10Display part: Horizontal piping erection sensor
(Display part~Cable between the sensor 10m)
*Sensor sparate
4.Display angle
Not availableDisplay angle: Front side, upward

(3)Display angle: Front side, rightpward

(6)Display angle: Front side, downward

(9)Display angle: Front side, leftward
5.Piping diameter
(*3)

40ADiameter of fixed pipe for display unit Nominal diameter: φ48.6

50ADiameter of fixed pipe for display unit Nominal diameter: φ60.5
6.Display/Calibration
Pressurization, Negative pressure, Compound pressureSpecify the values and units of display/calibration ranges
(*1) Specify from the list of ranges.
7.Rated Capacity(R.C.)
00550kPa

010100kPa

020200kPa(*4)

021200kPa(*4)
(Specify this model at calibration for compound pressure if "focus on negative pressure" has been selected.)

030300kPa(*4)

031300kPa(*4)
(Specify this model at calibration for compound pressure if "focus on negative pressure" has been selected.)

050500kPa

1001000kPa

3003MPa [Display/Calibration: Specify 3.00MPa][Make to order]
(Withstand pressure:150%R.C.
ISO Cap nut and Screw mount only)
8.Pressure Port Type/Size
F1ISO Ferrule 1.5S

F2ISO Ferrule 2S

F3ISO Ferrule 2.5S[Make to order]

F4ISO Ferrule 3S[Make to order]

F6ISO Ferrule 4S[Make to order]

V50AVARIVENT® DN50[Make to order]

V65AVARIVENT® DN65[Make to order]

V80AVARIVENT® DN80[Make to order]

V100AVARIVENT® DN100[Make to order]

R1ISO Cap nut 1.5S[Make to order] Hexagon nut included (HEX61)

R2ISO Cap nut 2S[Make to order] Hexagon nut included (HEX76)

M0Screw mount type simple substance
Dedicated O-ring included (×1)

M1JIS20K50A With flange, Dedicated O-ring included (×1)

M2JIS20K80A With flange, Dedicated O-ring included (×1)
9.Pressure Port Material
BlankSUS316L, Electro-Chemical Buffing(Ry0.7)
⑦Supports all rated capacities.
⑧Supports all pressure port type/size.

HS1Hastelloy C276, Electro-Chemical Buffing(Ry0.7)
⑦Rated capacitor can be selected from among 300, 500 and 1000kPa.
⑧Pressure port type/size can be selected from among F1, F2, F3 and M0.
[Make to order]
Negative pressure and compound pressure are not supported

J4LSUS329J4L, Buffing(#400)
⑦Rated capacitor can be selected from among 300, 500 and 1000kPa.
⑧Pressure port type/size can be selected from among F1, F2, F3 and M0.
10.Limitation
P400%R.C.(3MPa is not selectable)

Blank150%R.C.(3MPa only)
11.PowerPG8A2 of 3 single alkali dry cell(LR6) (*5)(*6)

List of range(*1)

Rated capacitySpecification of display range
PressurizationCompound pressureNegative pressure
ModelRatingUnitkPaMPakPakPa
00550kPa5050.0-0.050(-50~50)(-50.0~50.0)-(-50)(-50.0)
010100100100.0-0.100Use the rated capacity of 200 kPa.(-100)-
020 or 021200200-0.200.200(-100~100)(-99.9~100.0)(-100~200)(-100)(-99.9)
030 or 31300300-0.300.300(-100~100)(-100~100)(-100~200 or 300)(-100)-
050500500-0.500.500(-100~500)(-.100~.500)[MPa]--
10010001000-1.001.000(-100~1000)(-.100~1.000)[MPa]--
3003MPa--3.00--(-0.10~3.00)[MPa]--
  • (*2) When auto power off is selected, it is possible to set whether to turn off the display automatically after "1 or 5 minutes" or to always keep power ON. (Default: 5 minutes)

  • (*3) In case of calibration for compound pressure, calibration is performed only for the positive pressure, and only measurement data are given for the negative pressure. In this case, acceptance criterion is within ±1%R.C. When focusing on the negative pressure, it is also possible to perform calibration for the negative pressure and to provide only measurement data (within ±1%R.C.) according to the request from the customer.
    Regarding calibration, specify 020, 030 (focus on positive pressure) or 021, 031 (focus on negative pressure) in ⑥ above when placing an order.

  • (*4) Battery: Two AA batteries are included.